OneView drivers
Note
The oneview drivers and hardware type, along with related interfaces to support OneView, have been deprecated, and should be expected to be removed from ironic in the Stein cycle. Please see storyboard for additional details.
Overview
HP OneView1 is a single integrated platform,
packaged as an appliance that implements a software-defined approach to
managing physical infrastructure. The appliance supports scenarios such
as deploying bare metal servers, for instance. In this context, the
HP OneView driver for ironic enables the users of OneView
to use ironic as a bare metal provider to their managed physical
hardware.
HPE OneView hardware is supported by the oneview
hardware type and the following classic drivers:
iscsi_pxe_oneviewagent_pxe_oneview
Classic Drivers
The iscsi_pxe_oneview and agent_pxe_oneview
drivers implement the core interfaces of an ironic Driver2,
and use the hpOneView3 library to provide
communication between ironic and OneView through OneView's REST API.
Note
Classic drivers will be deprecated in favor of Hardware Types.
To provide a bare metal instance there are four components involved in the process:
- The ironic service
- The ironic-inspector service (if using hardware inspection)
- The ironic driver for OneView, which can be:
-
- iscsi_pxe_oneview or
- agent_pxe_oneview
- The hpOneView library
- The OneView appliance
The role of ironic is to serve as a bare metal provider to OneView's
managed physical hardware and to provide communication with other
necessary OpenStack services such as Nova and Glance. When ironic
receives a boot request, it works together with the ironic OneView
driver to access a machine in OneView, the hpOneView being
responsible for the communication with the OneView appliance.
From the Newton release on, OneView drivers enables a new feature called dynamic allocation of nodes4. In this model, the driver allocates resources in OneView only at boot time, allowing idle resources in ironic to be used by OneView users, enabling actual resource sharing among ironic and OneView users.
Since OneView can claim nodes in available state at any
time, a set of tasks runs periodically to detect nodes in use by
OneView. A node in use by OneView is placed in manageable
state and has maintenance mode set. Once the node is no longer in use,
these tasks will make place them back in available state
and clear maintenance mode.
Prerequisites
The following requirements apply for both
iscsi_pxe_oneview and agent_pxe_oneview
drivers:
OneView applianceis the HP physical infrastructure manager to be integrated with the OneView drivers.Minimum version supported is 2.0.
hpOneViewis a python package containing a client to manage the communication between ironic and OneView.Install the
hpOneViewmodule to enable the communication. Minimum version required is 4.4.0 but it is recommended to install the most up-to-date version:$ pip install "hpOneView>=4.4.0"ironic-inspectorif using hardware inspection.
Tested platforms
The OneView appliance used for testing was the OneView 2.0.
The Enclosure used for testing was the
BladeSystem c7000 Enclosure G2.The drivers should work on HP Proliant Gen8 and Gen9 Servers supported by OneView 2.0 and above, or any hardware whose network can be managed by OneView's ServerProfile. It has been tested with the following servers:
- Proliant BL460c Gen8
- Proliant BL460c Gen9
- Proliant BL465c Gen8
- Proliant DL360 Gen9
Notice that for the driver to work correctly with Gen8 and Gen9 DL servers in general, the hardware also needs to run version 4.2.3 of iLO, with Redfish enabled.
Hardware Interfaces
The oneview hardware type supports the following
hardware interfaces:
- boot
-
Supports only
pxe. It can be enabled by using the[DEFAULT]enabled_boot_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_boot_interfaces = pxe
- console
-
Supports only
no-console. It can be enabled by using the[DEFAULT]enabled_console_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_console_interfaces = no-console
- deploy
-
Supports
oneview-directandoneview-iscsi. The default isoneview-iscsi. They can be enabled by using the[DEFAULT]enabled_deploy_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_deploy_interfaces = oneview-iscsi,oneview-direct
- inspect
-
Supports
oneviewandno-inspect. The default isoneview. They can be enabled by using the[DEFAULT]enabled_inspect_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_inspect_interfaces = oneview,no-inspect
- management
-
Supports only
oneview. It can be enabled by using the[DEFAULT]enabled_management_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_management_interfaces = oneview
- power
-
Supports only
oneview. It can be enabled by using the[DEFAULT]enabled_power_interfacesoption inironic.confas given below:[DEFAULT] enabled_hardware_types = oneview enabled_power_interfaces = oneview
The oneview hardware type also supports the standard
network and storage interfaces.
To enable the same feature set as provided by all oneview classic drivers, apply the following configuration:
[DEFAULT]
enabled_hardware_types = oneview
enabled_deploy_interfaces = oneview-direct,oneview-iscsi
enabled_inspect_interfaces = oneview
enabled_power_interfaces = oneview
enabled_management_interfaces = oneviewThe following commands can be used to enroll a node with the same
feature set as one of the classic drivers, but using the
oneview hardware type:
oneview-direct:openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver oneview \ --deploy-interface oneview-directoneview-iscsi:openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver oneview \ --deploy-interface oneview-iscsi
Drivers
iscsi_pxe_oneview driver
Overview
iscsi_pxe_oneview driver uses PXEBoot for boot and
ISCSIDeploy for deploy.
Configuring and enabling the driver
Add
iscsi_pxe_oneviewto the list ofenabled_driversin yourironic.conffile. For example:enabled_drivers = iscsi_pxe_oneviewUpdate the [oneview] section of your
ironic.conffile with your OneView credentials and CA certificate files information.
Note
An operator can set the periodic_check_interval option
in the [oneview] section to set the interval between running the
periodic check. The default value is 300 seconds (5 minutes). A lower
value will reduce the likelihood of races between ironic and OneView at
the cost of being more resource intensive.
Restart the ironic conductor service. For Ubuntu users, do:
$ sudo service ironic-conductor restart
See /install/index
for more information.
Deploy process
Here is an overview of the deploy process for this driver:
- Admin configures the Proliant baremetal node to use
iscsi_pxe_oneviewdriver. - ironic gets a request to deploy a Glance image on the baremetal node.
- Driver sets the boot device to PXE.
- Driver powers on the baremetal node.
- ironic downloads the deploy and user images from a TFTP server.
- Driver reboots the baremetal node.
- User image is now deployed.
- Driver powers off the machine.
- Driver sets boot device to Disk.
- Driver powers on the machine.
- Baremetal node is active and ready to be used.
agent_pxe_oneview driver
Overview
agent_pxe_oneview driver uses PXEBoot for boot and
AgentDeploy for deploy.
Configuring and enabling the driver
Add
agent_pxe_oneviewto the list ofenabled_driversin yourironic.conf. For example:enabled_drivers = pxe_ipmitool,agent_pxe_oneviewUpdate the [oneview] section of your
ironic.conffile with your OneView credentials and CA certificate files information.
Note
An operator can set the periodic_check_interval option
in the [oneview] section to set the interval between running the
periodic check. The default value is 300 seconds (5 minutes). A lower
value will reduce the likelihood of races between ironic and OneView at
the cost of being more resource intensive.
Restart the ironic conductor service. For Ubuntu users, do:
$ service ironic-conductor restart
See /install/index
for more information.
Deploy process
Here is an overview of the deploy process for this driver:
- Admin configures the Proliant baremetal node to use
agent_pxe_oneviewdriver. - ironic gets a request to deploy a Glance image on the baremetal node.
- Driver sets the boot device to PXE.
- Driver powers on the baremetal node.
- Node downloads the agent deploy images.
- Agent downloads the user images and writes it to disk.
- Driver reboots the baremetal node.
- User image is now deployed.
- Driver powers off the machine.
- Driver sets boot device to Disk.
- Driver powers on the machine.
- Baremetal node is active and ready to be used.
Hardware inspection
OneView drivers for ironic have the ability to do hardware
inspection. Hardware inspection is the process of discovering hardware
properties like memory size, CPU cores, processor architecture and disk
size, of a given hardware. OneView drivers do in-band inspection, that
involves booting a ramdisk on the hardware and fetching information
directly from it. For that, your cloud controller needs to have the
ironic-inspector component 5
running and properly enabled in ironic's configuration file.
See6 for more information on how to
install and configure ironic-inspector.
Registering a OneView node in ironic
Nodes configured to use any of the OneView drivers should have the
driver property set to iscsi_pxe_oneview or
agent_pxe_oneview. Considering our context, a node is the
representation of a Server Hardware in OneView, and should
be consistent with all its properties and related components, such as
Server Hardware Type, Server Profile Template,
Enclosure Group, etc. In this case, to be enrolled, the
node must have the following parameters:
- In
driver_infoserver_hardware_uri: URI of theServer Hardwareon OneView.
- In
properties/capabilitiesserver_hardware_type_uri: URI of theServer Hardware Typeof theServer Hardware.server_profile_template_uri: URI of theServer Profile Templateused to create theServer Profileof theServer Hardware.enclosure_group_uri(optional): URI of theEnclosure Groupof theServer Hardware.
To enroll a node with any of the OneView drivers, do:
$ openstack baremetal node create --driver $DRIVER_NAME
To update the driver_info field of a newly enrolled
OneView node, do:
$ openstack baremetal node set $NODE_UUID --driver-info server_hardware_uri=$SH_URI
To update the properties/capabilities namespace of a
newly enrolled OneView node, do:
$ openstack baremetal node set $NODE_UUID \
--property capabilities=server_hardware_type_uri:$SHT_URI,enclosure_group_uri:$EG_URI,server_profile_template_uri=$SPT_URI
In order to deploy, ironic will create and apply, at boot time, a
Server Profile based on the
Server Profile Template specified on the node to the
Server Hardware it represents on OneView. The URI of such
Server Profile will be stored in
driver_info.applied_server_profile_uri field while the
Server is allocated to ironic.
The Server Profile Templates and, therefore, the
Server Profiles derived from them MUST comply with the
following requirements:
- The option MAC Address in the Advanced section of
Server Profile/Server Profile Templateshould be set to Physical option; - Their first Connection interface
should be:
- Connected to ironic's provisioning network and;
- The Boot option should be set to primary.
Node ports should be created considering the MAC address of
the first Interface of the given
Server Hardware.
To tell ironic which NIC should be connected to the provisioning network, do:
$ openstack baremetal port create --node $NODE_UUID $MAC_ADDRESS
For more information on the enrollment process of an ironic node, see
enrollment.
For more information on the definitions of
Server Hardware, Server Profile,
Server Profile Template and other OneView entities, refer
to 7 or browse Help in your OneView
appliance menu.
Note
Ironic manages OneView machines either when they have a Server Profile applied by the driver or when they don't have any Server Profile. Trying to change the power state of the machine in OneView without first assigning a Server Profile will lead to allowing Ironic to revert the power state change. Ironic will NOT change the power state of machines which the Server Profile was applied by another OneView user.
3rd Party Tools
In order to ease user manual tasks, which are often time-consuming, we provide useful tools that work nicely with the OneView drivers.
ironic-oneview-cli
The ironic-oneView CLI is a command line interface for
management tasks involving OneView nodes. Its features include a
facility to create of ironic nodes with all required parameters for
OneView nodes, creation of Nova flavors for OneView nodes.
For more details on how Ironic-OneView CLI works and how to set it up, see 8.
ironic-oneviewd
The ironic-oneviewd daemon monitors the ironic inventory
of resources and provides facilities to operators managing OneView
driver deployments.
For more details on how Ironic-OneViewd works and how to set it up, see9.
References
HP OneView - https://www.hpe.com/us/en/integrated-systems/software.html↩︎
architecture_drivers↩︎hpOneView - https://pypi.org/project/hpOneView↩︎
Dynamic Allocation in OneView drivers - https://specs.openstack.org/openstack/ironic-specs/specs/not-implemented/oneview-drivers-dynamic-allocation.html↩︎
ironic-inspector - https://docs.openstack.org/ironic-inspector/latest/↩︎
ironic-inspector install - https://docs.openstack.org/ironic-inspector/latest/install/index.html↩︎
HP OneView - https://www.hpe.com/us/en/integrated-systems/software.html↩︎
ironic-oneview-cli - https://pypi.org/project/ironic-oneview-cli/↩︎
ironic-oneviewd - https://pypi.org/project/ironic-oneviewd/↩︎