Inspector Support ================= Ironic supports in-band inspection using the ironic-inspector_ project. This is the original in-band inspection implementation, which is being gradually phased out in favour of a similar implementation inside Ironic proper. It is supported by all hardware types, and used by default, if enabled, by the ``ipmi`` hardware type. The ``inspector`` *inspect* interface has to be enabled to use it: .. code-block:: ini [DEFAULT] enabled_inspect_interfaces = inspector,no-inspect If the ironic-inspector service is not registered in the service catalog, set the following option: .. code-block:: ini [inspector] endpoint_override = http://inspector.example.com:5050 In order to ensure that ports in Bare Metal service are synchronized with NIC ports on the node, the following settings in the ironic-inspector configuration file must be set: .. code-block:: ini [processing] add_ports = all keep_ports = present Managed and unmanaged inspection -------------------------------- There are two modes of in-band inspection: *managed* inspection and *unmanaged* inspection. See :doc:`/admin/inspection/managed` for more details. .. _ironic-inspector: https://pypi.org/project/ironic-inspector .. _python-ironicclient: https://pypi.org/project/python-ironicclient